Lincoln sp 125 plus problems - 02-04-2010 #1 Guard Solderer Join Date Feb 2010 Posts 4 Post Thanks / Like SP125 plus problems? Hello, I've had this for years w/gas bottle, and loved it so far! A few days ago trying to weld-up a snow blade for a 4-wheeler, It did fine for about 10 minutes, about 3-4 ins. of bead at a time, then quit putting anything out.

 
Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. . Inventario pick a part monrovia

Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.A short stick of welding filler metal consisting of a core of bare electrode covered by chemical or metallic materials that provide shielding of the welding arc against the surrounding air. It also completes the electrical circuit, thereby creating the arc. (Also known as SMAW, or Stick Metal Arc Welding.)Lincoln Powermig 255. $2,200. Mount Vernon Triumph 2 & 4 Post Lifts, Low Price, Free Shipping, No Tax!!! $115. 0% 12 month Financing!!! Call or Text (866)774-7743Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Need some help with my "new to me" welder. I am having problems with my welder, its a Lincoln SP250 welder (ditigal version). I am getting a lot of sticking and "blast off" with weld porosity. The weld are are narrow and ropy, the gun are "kicking" back at me. I changed the liner, tip and nozzle. I am using .35 solid steel with 75/25 Argon/CO2.Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.If you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusSP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantSOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.Step 4: Re-seat the Trigger. place the trigger back into its housing. the little tabs sticking out at the front and back should fit easily into depressions in the gun body. There will be some compression of the spring so you may need to keep a finger on the trigger to get it to stay put. After you are sure that everything is aligned properly ...02-04-2010 #1 Guard Solderer Join Date Feb 2010 Posts 4 Post Thanks / Like SP125 plus problems? Hello, I've had this for years w/gas bottle, and loved it so far! A few days ago trying to weld-up a snow blade for a 4-wheeler, It did fine for about 10 minutes, about 3-4 ins. of bead at a time, then quit putting anything out.My second , a Lincoln SP125 Plus, lots of years ago. Use it weekly. I mainly do body panel rust repair on vintage sports cars, ie thicker carbon steel. My son is 50 miles away with projects too. I need to stage a welder there. I liked my welder so much I found one like it for him, but it needs some parts. I know Lincoln did't make it.1994 lincoln town car. radio and power antenna don't work. fuses are good everything else works. what is the problem? ... lincoln sp 125 plus glowworm 30 cxi ...Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.Problem it's will be great for tack welds only.There was a guy doing production aluminum back in the day, The SP-125 is a nice auto-body rig, and exhaust type work. A machine like a Klutch 140si with spool-gun is light years ahead of the Lincoln in laying beads down..I would like to have a SP-125/135 in my shop.It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.Drive Roll .035" For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $28.99. Save up to 5% when you buy more. Buy ...It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.Hello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric Equipment1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantLincoln Electriclincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderNo Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.I have a Lincoln 135 Pro that I use all the time for sheetmetal. Works great, on the smaller stuff no problem. If you have the power, and the dough, go bigger, but if you have a 1927 house like me, with 120 wiring, its a good machine. When I upgrade my power, I will get a bigger machine for heavier stuff. flatheadhero, Mar 19, 2007.Lincoln SP 125 Plus. $500 ... Save. Save. Share. Details. Condition. Used - Good. It's a little dusty but it works great no problems at all and that's a good price ...Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Premium quality 100Amp replacement MIG gun stinger torch, 10-foot (3m) cable, fully compatible with Lincoln Magnum 100L (K530-5) Usually Lincoln Magnum 100L (K530-5) MIG gun can be found on SP-85, SP-100, SP-100I, SP-100T, SP-125 Plus, SP-130T, SP-135 Plus, SP-140I, SP-155, SP-170, SP-170I, SP-170T, SP-175 Plus, SP-175T, Handy MIG 170I, MIG Pak 10, MIG Pak 15, Pro 100, Pro 155, Pro-Core 100 ...Problem it's will be great for tack welds only.There was a guy doing production aluminum back in the day, The SP-125 is a nice auto-body rig, and exhaust type work. A machine like a Klutch 140si with spool-gun is light years ahead of the Lincoln in laying beads down..I would like to have a SP-125/135 in my shop.Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderYou need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,A short stick of welding filler metal consisting of a core of bare electrode covered by chemical or metallic materials that provide shielding of the welding arc against the surrounding air. It also completes the electrical circuit, thereby creating the arc. (Also known as SMAW, or Stick Metal Arc Welding.)Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. 1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.Lincoln Electric. $118.81 ) +Free Shipping. SKU: S24355-4. Quantity: Decrease Quantity: Increase Quantity: Only left in stock! Adding to cart… category.add_cart ...LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.Nov 25, 2011 · Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool. If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric EquipmentMar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)Your #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. Drive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro...

Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.. What time do wendy

lincoln sp 125 plus problems

Contact us by phone at 888-935-3877. Service & Distributor Locator. Print & Pdf Publications: REQUEST LITERATURE. COUNTERTOP PARTS GUIDE. (20 mb PDF) service navigator: video tips.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.Looking for parts for Lincoln mig welder sp130t, – – Looking for parts for Lincoln mig welder sp130t, need part m15787-2, g1839,and drive roll, Any idea where to – MIG Welders question Lincoln Welder – Farm Supply Ranch – lincoln electric k639 1 suction head manual 12 inch lincoln sp 125 plus arc welder in excellent condition 9.99 ...Nov 25, 2011 · Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool. If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,Drive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric EquipmentI bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13.